Commissioning-Assistant

Commissioning-Assistant


The Commissioning-Assistant (aka Inbetriebnahme-Helfer) is an easy-to-use tools for service -., And maintenance personnel in the field of measurement and control technology -., And control technology.
For calculations, among others, the typical standard signals such as 0 ... 20 and 4 ... 20 mA, 0 ... 5 and 1 ... 5 V, 0 ... 10 and 2 ... 10 volts are available.
Furthermore, 12-bit values/signals as 0 ... 4095 and 819 ... 4095 digit and 16-bit values/signals as 0 ... 65535 and 13107 ... 65535 digit are calculated.
For data transfers via a digital interface (Profibus, Modbus, OPC) to Computerized Emission Evaluators (Environmental Data Managment Systems) available for calculations, the dimensionless scaling -10000 ... +10000.
Especially for pneumatic transmitter is the signal unit 3 ... 15 psi for calculations.
Non-linear values / signals can be calculated accordingly.
For temperature measurements in each case is a calculation for platinum resistance thermometers and thermocouples are available.
It can alternately the temperature -., And resistance values ​​and temperature -., And thermoelectric voltage are calculated.
In the calculation of temperature measurements with thermocouples (except type B) the reference junction temperature can in fixed steps or free in the
Range of -50 ... +100 °C / 223.15 ... 373.15 K / -58 ... +212 °F / 401.67 ... 671.67 °Ra / -40 ... +80 °Ré be entered.
The setting of the reference junction temperature of the thermocouple type B can not be changed in the app and is preset to 0 °C / 273.15 K / 32 °F / 491.67 °Ra / 0 °Ré.
Who sometimes just from a measured value must calculate a signal value or vice versa, so this has done fairly quickly and easily with the Commissioning-Assistant.

Important note; All information without guarantee!

Example of use:
A shift electrician to check the measurement path of a flow measurement and grinds with his instrument in the measuring circuit.
He knows that there is a 4 ... 20 mA signal, measures 7.93 mA and knows the range 0 ... 120000 Bm3/h
He also knows that the differential is not square root and thus a non-linear signal concerns.
This information makes it in the startup-helper and as a result receives 59472.68 Bm3 / h, equivalent to 49.56% of the measuring range.
So now he knows exactly what needs to display a PLS at 7.93 mA.
The table (only when signal) lists in 25% increments all values corresponding to at a review of the test section through a calibrator to verify the readings immediately.

In the opposite case, he might have to simulate the mA signal on PLS to a specific value.
It should be, for example, in the PLS in the measurement of the volume flow measurement on 90000 Bm3 / h simulated / frozen, according to the relevant information he receives as a result of 13.0 mA and can simulate the analog input it.

It is to be checked, for example, a proportional amplifier input 4 ... 20 mA / output -10 ... +10 Volt
The corresponding analog output from the PLS outputs 13.87 mA, but what would the shift electrician at the output of the proportional amplifier can Measure to?
The result is: 2.34 volts

* The Commissioning-Assistant is free, absolutely free of advertising, does not collect any data, that requires no internet and no special permissions!

Keywords/Stichworte/Tags: Inbetriebnahme, Inbetriebsetzung, IBN, IBS, Spannung, Strom, Temperatur, Leittechnik, Messtechnik, Messwert, Signal, Einheit, Überprüfung, Helfer, messen, berechnen, prüfen, testen, simulieren, commissioning, voltage, current, temperature, process control, instrumentation, measurement, signal unit, review, assistent, analyze, check, calculate, test, simulate

Recent changes:
Important; Android version 4.x.x is required!
Important; only devices with a resolution of 400x800 are supported!

Version 2.0 / Build 251
- Added signal type / scale 3 ... 15 psi for
calculations with pneumatic transmitters

Version 2.0 / Build 250
- Find and eliminate the cause of the unneeded
permission "modify secure system settings"
- bug Fix

Version 2.0 / Build 249
- Fixed bug in the table
- Optimizations
Add to list
Free
87
4.4
User ratings
31
Installs
1,000+
Concerns
0
File size
423 kb
Screenshots
Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant Screenshot of Commissioning-Assistant

About Commissioning-Assistant
The Commissioning-Assistant (aka Inbetriebnahme-Helfer) is an easy-to-use tools for service -., And maintenance personnel in the field of measurement and control technology -., And control technology.
For calculations, among others, the typical standard signals such as 0 ... 20 and 4 ... 20 mA, 0 ... 5 and 1 ... 5 V, 0 ... 10 and 2 ... 10 volts are available.
Furthermore, 12-bit values/signals as 0 ... 4095 and 819 ... 4095 digit and 16-bit values/signals as 0 ... 65535 and 13107 ... 65535 digit are calculated.
For data transfers via a digital interface (Profibus, Modbus, OPC) to Computerized Emission Evaluators (Environmental Data Managment Systems) available for calculations, the dimensionless scaling -10000 ... +10000.
Especially for pneumatic transmitter is the signal unit 3 ... 15 psi for calculations.
Non-linear values / signals can be calculated accordingly.
For temperature measurements in each case is a calculation for platinum resistance thermometers and thermocouples are available.
It can alternately the temperature -., And resistance values ​​and temperature -., And thermoelectric voltage are calculated.
In the calculation of temperature measurements with thermocouples (except type B) the reference junction temperature can in fixed steps or free in the
Range of -50 ... +100 °C / 223.15 ... 373.15 K / -58 ... +212 °F / 401.67 ... 671.67 °Ra / -40 ... +80 °Ré be entered.
The setting of the reference junction temperature of the thermocouple type B can not be changed in the app and is preset to 0 °C / 273.15 K / 32 °F / 491.67 °Ra / 0 °Ré.
Who sometimes just from a measured value must calculate a signal value or vice versa, so this has done fairly quickly and easily with the Commissioning-Assistant.

Important note; All information without guarantee!

Example of use:
A shift electrician to check the measurement path of a flow measurement and grinds with his instrument in the measuring circuit.
He knows that there is a 4 ... 20 mA signal, measures 7.93 mA and knows the range 0 ... 120000 Bm3/h
He also knows that the differential is not square root and thus a non-linear signal concerns.
This information makes it in the startup-helper and as a result receives 59472.68 Bm3 / h, equivalent to 49.56% of the measuring range.
So now he knows exactly what needs to display a PLS at 7.93 mA.
The table (only when signal) lists in 25% increments all values corresponding to at a review of the test section through a calibrator to verify the readings immediately.

In the opposite case, he might have to simulate the mA signal on PLS to a specific value.
It should be, for example, in the PLS in the measurement of the volume flow measurement on 90000 Bm3 / h simulated / frozen, according to the relevant information he receives as a result of 13.0 mA and can simulate the analog input it.

It is to be checked, for example, a proportional amplifier input 4 ... 20 mA / output -10 ... +10 Volt
The corresponding analog output from the PLS outputs 13.87 mA, but what would the shift electrician at the output of the proportional amplifier can Measure to?
The result is: 2.34 volts

* The Commissioning-Assistant is free, absolutely free of advertising, does not collect any data, that requires no internet and no special permissions!

Keywords/Stichworte/Tags: Inbetriebnahme, Inbetriebsetzung, IBN, IBS, Spannung, Strom, Temperatur, Leittechnik, Messtechnik, Messwert, Signal, Einheit, Überprüfung, Helfer, messen, berechnen, prüfen, testen, simulieren, commissioning, voltage, current, temperature, process control, instrumentation, measurement, signal unit, review, assistent, analyze, check, calculate, test, simulate

Recent changes:
Important; Android version 4.x.x is required!
Important; only devices with a resolution of 400x800 are supported!

Version 2.0 / Build 251
- Added signal type / scale 3 ... 15 psi for
calculations with pneumatic transmitters

Version 2.0 / Build 250
- Find and eliminate the cause of the unneeded
permission "modify secure system settings"
- bug Fix

Version 2.0 / Build 249
- Fixed bug in the table
- Optimizations
User reviews of Commissioning-Assistant
Write the first review for this app!
Android Market Comments
A Google User
Sep 12, 2014
Excellent tool for all instrumentation engineers It's really an excellent tool. As the name suggests it is good for commissioning engineers. Apart from the unavailability of C type thermocouple it is up to the mark. Looking up for more improvements in the app.
A Google User
Aug 17, 2014
Great App!!!, but... Wheres the 3-15 psi signal??????
A Google User
Jul 16, 2014
Nice Perfect
A Google User
May 10, 2014
Very useful
A Google User
May 6, 2014
Fine, very useful during shop calibration.