Select ASSE backflow devices by app. Hazard classification. Code compliant.
5+ downloads
About Backflow Device Selector Tool
Backflow Device Selector Tool is a tools app developed by ZkDev.
How many times has Backflow Device Selector Tool been downloaded?
Backflow Device Selector Tool has been downloaded 8 times. In the last 30 days, the app was downloaded 1 times.
What is the rating of Backflow Device Selector Tool?
Backflow Device Selector Tool has no ratings yet.
Is Backflow Device Selector Tool free?
Backflow Device Selector Tool is free to download. The APK download size is 19.98 MB. The latest version available is 1.0.5. The last update was on June 12, 2026.
What are the requirements for Backflow Device Selector Tool?
The app has a content rating of Everyone. The app has been available on Google Play April 2026.
Description
Backflow Prevention Device Selector is a professional plumbing calculator and reference tool for master plumbers, backflow prevention testers, water utility inspectors, and building code officials. Select the correct ASSE-certified backflow prevention device for any application in seconds, with full hazard classification and IPC/UPC code compliance verification. Works 100% offline on the job site with zero internet dependency — designed for water safety compliance.
FEATURES • Device Selection by Application: 17 application types — irrigation, boiler (with and without chemical treatment), fire protection, laboratory, medical/dental equipment, chemical feed, commercial laundry, food processing, pool/spa, solar heating, carbonator/beverage dispenser, hose connection, toilet and urinal flush valves, commercial dishwasher, and cooling tower • 8 Backflow Device Types: Atmospheric Vacuum Breaker (AVB), Hose Vacuum Breaker (HVB), Spill-Resistant Vacuum Breaker (SVB), Double Check Valve Assembly (DCVA), Pressure Vacuum Breaker (PVB), Reduced Pressure Principle Device (RPZ), Anti-Siphon Device (AG), and Dual Check Valve • Hazard Classification: Automatic high vs. low hazard classification for each application type to ensure correct protection level • Standards Reference: ASSE 1001 (AVB), 1011 (hose vacuum breaker), 1013 (RPZ), 1015 (DCVA), 1020 (PVB), 1024 (dual check), 1056 (SVB) and ASME A112.1.2 (air gap) • Ranked Recommendations: Devices ranked by preference and code compliance for your specific application • Pressure and Temperature Requirements: Verify device pressure and temperature compatibility for your specific installation • Installation Notes: Code-specific installation requirements and location constraints for each device type
HOW IT WORKS 1. Select your application type from the dropdown (irrigation, boiler, fire protection, etc.) 2. The app automatically classifies the hazard level (high or low) 3. View all compatible backflow prevention devices ranked by preference 4. See ASSE standard references and full device specifications 5. Save calculations to history, export to PDF for code inspections and permits
PERFECT FOR • Master plumbers and journeyman plumbers performing backflow prevention installations • Backflow prevention testers and cross-connection control specialists • Water utility inspectors verifying compliance with code standards • Plumbing contractors and mechanical estimators • Building code officials and inspectors • Plumbing apprentices learning ASSE standards and device selection
OPTIONAL PRO UPGRADE — $2.99 ONE-TIME IN-APP PURCHASE The following features require a separate one-time in-app purchase. They are not required to use the calculator: • Unlimited saved calculation history • PDF export of results • Dark theme • Ad-free experience
STANDARDS & COMPLIANCE ASSE 1001 Atmospheric Vacuum Breaker, ASSE 1011 Hose Connection Vacuum Breaker, ASSE 1013 Reduced Pressure Principle Assembly, ASSE 1015 Double Check Valve Assembly, ASSE 1020 Pressure Vacuum Breaker, ASSE 1024 Dual Check Valve, ASSE 1056 Spill-Resistant Vacuum Breaker, and ASME A112.1.2 Air Gap. Also references IPC (International Plumbing Code) and UPC (Uniform Plumbing Code) cross-connection control requirements. Always confirm with your local code official and water purveyor.
OFFLINE & PRIVACY • Works 100% offline - no internet required on the job site • No account needed - instant access without signup • No data collection or cloud sync - all calculations stored locally on your device • No tracking or analytics - your work stays completely private
Part of PlumbTools Suite - professional plumbing calculators and code reference tools for plumbers, pipefitters, and plumbing contractors. Reduce calculation errors, ensure code compliance, and work faster in the field with plumbing code calculators.
Recent changes: Corrected standards references: air gap is ASME A112.1.2 (not ASSE 1001) and the hose connection vacuum breaker is ASSE 1011. Safety fixes: solar heating (glycol), toilet/urinal flush valves are now classified high hazard (DCVA removed where not legal), and a separate "Boiler with chemical treatment" application (RPZ) was added.
Get a detailed PDF report for Backflow Device Selector Tool with download trends, rating history,
and key performance statistics — useful for competitive research or tracking your own app.
Learn more
Are you the developer of this app? Join us for free to see more information about your app and learn how we can help you promote and earn money with your app.
Each subscription will automatically renew 3 days before the expiration date for
the same time period. Subscriptions can be cancelled at any time before the renewal.