SCADAfeathery for Modbus is a niche app, with 2.5 thousand installs. It doesn't have enough ratings yet to judge what users think.
SCADAfeathery for Modbus is made and published by
AutomationServices.
AppBrain is an independent app data site and isn't affiliated with AutomationServices.
The app name, icon, screenshots and description belong to AutomationServices and are shown as
published on Google Play.
About SCADAfeathery for Modbus
SCADAfeathery for Modbus is a productivity app developed by AutomationServices.
How many times has SCADAfeathery for Modbus been installed?
SCADAfeathery for Modbus has been installed 2.5 thousand times. In the last 30 days, the app was installed 0 times.
What is the rating of SCADAfeathery for Modbus?
SCADAfeathery for Modbus has no ratings yet.
Is SCADAfeathery for Modbus free?
SCADAfeathery for Modbus is free. The last update was on October 25, 2022.
What are the requirements for SCADAfeathery for Modbus?
The app has a content rating of Everyone. The app has been available on Google Play since October 2022.
Description by AutomationServices(from Google Play)
You have a Modbus device and want to visualize it by a few easy steps? Are you an owner of WAGO (P-)FC series 750/758? Are your writing CoDeSys 2.3 programms on WAGO-devices and want to see the calculation results on your android device? Then this application is that what you are looking for. After only 3 steps the definition of the visualization is complete: 1) Define your Modbus network. 2) Create data points. 3) Define the representation of the data points
You can define any number of devices on the network. The devices (called network services) are stored in the application, and can be used later. For each device (network service), you can assign its data points. The definition of a datapoint consists of the following parameters: - Designation of the datapoint
- Datatype of the datapoint (based on IEC61131-Datatypes) - Datatype STRING requiers the length in bytes additionaly - Read-Defintion: FC-Code (FC1, FC2, FC3, FC4) - Read-Definition: modbus address (register or coil, depends on FC-Code) - Read-Definition: bit offset, within the addressed modbus register or coil - Write-Defintion: FC-Code (FC5, FC6, FC15, FC16) - Write-Definition: modbus address (register or coil, depends on FC-Code) - Write-Definition: bit offset, within the addressed modbus register or coil
For WAGO-Devices this parameters are filled out automaticaly.
Each data point can be visualized by (at the moment) 4 presentation items: + Textbox + Slider (0..100) + Switch + XY-Plot Your are able to scale the values by the linear polynom (f(x)=m*x+b). You can define min/max-ranges, that are monitored at the runtime. There is a constant monitoring of the data point availability , you will be notified if the datapoint is not accessable anymore.
Modbus-communication
The communication is possible through Wifi and 3G/4G- Networks. Following modbus function codes are supported: FC1, FC2, FC3, FC4,FC5,FC6,FC15,FC16. An real-time algorithm used for communication task guarantees that the calculated cycle-time for each communication-job will be kept. The cycle-time is linearly proportional to the number of datapoints within the perspective.
Special features for WAGO-Devices
This appliation contains a database with all at the moment existing WAGO-Controllers and Couplers of the series 750/758. There is also modbus process image data about all terminals of the series 750/753.
You have defined your WAGO node already as network service? Then mark the discovered devices as WAGO device and scan the node. The connected terminals will be recognized and the full process image for modbus will be stored. Now you no longer have to calculate the address of the terminal in the process image. Just select the terminal and the channel of the terminal from the node description and make it to a data point. Do you have a PFC (programmable WAGO coupler)? Then it is possible to you to define a datapoint just by entereing of the IEC61131-address. Just enter the %I, %Q, %M address of your programm variable and the application converts this information into accoridn modbus-address on the network. Hint: Consider the PI-Assignment-Setting from CoDeSys if you want the write-access to kbus-terminals.
Get a detailed PDF report for SCADAfeathery for Modbus with download trends, rating history,
and key performance statistics — useful for competitive research or tracking your own app.
Learn more
Are you the developer of this app? Join us for free to see more information about your app and learn how we can help you promote and earn money with your app.
Each subscription will automatically renew 3 days before the expiration date for
the same time period. Subscriptions can be cancelled at any time before the renewal.