SteriProof: Autoclave Logbook
SteriProof: Autoclave Logbook is made and published by ClearStack Apps. AppBrain is an independent app data site and isn't affiliated with ClearStack Apps. The app name, icon, screenshots and description belong to ClearStack Apps and are shown as published on Google Play.
AppBrain's verdict
NewNiche- Installs
- 2
- Last updated
- September 24, 2026
- Ads
- Contains ads
- Size
- 26.4 MB
SteriProof: Autoclave Logbook came out 61 days ago. It is a niche app, with 2 installs. It doesn't have enough ratings yet to judge what users think.
User feedback
Ratings and reviews on Google PlayComments on SteriProof: Autoclave Logbook for Android
We don't have enough comments to show example comments. Please check back later.
Store listing
By ClearStack Apps, from Google Play“Autoclave cycle log, timed spore tests, load review list and audit PDF.”
Description by ClearStack Apps Written by the developer, not by AppBrain. Click to read.
WHAT IT DOES
Multi-autoclave dashboard
Every sterilizer on one screen. Each chamber shows its recorded test status, what is overdue and any failed record, so you can see where a chamber stands before you open it.
Cycle and load records
Log the cycle number, temperature, pressure, hold time, load contents and operator for each run. Temperature in C or F, pressure in bar or psi. If an entered value is below the target for the selected cycle, SteriProof flags that record for review.
Chemical indicator photos
Attach a photo of the indicator tape or Class 5 strip to the load record it belongs to, so it is filed with the cycle rather than in a drawer.
Biological indicator log with a timed read
Start a spore test and SteriProof stores the incubation start and the due time for the incubation period you selected. The result field stays locked until the device clock reaches that due time, and a notification tells you when it is ready to read. The processed indicator and its matching control are recorded separately, and a control that did not grow is shown as an invalid test rather than a pass.
Load review list after a positive result
When a biological indicator comes back positive, SteriProof lists the loads processed on that chamber since its previous negative result. The list supports the review carried out by the person responsible for infection control. It does not determine what must be recalled or reprocessed.
Autoclave maintenance log
Bowie-Dick, helix, vacuum leak and automatic control test records, plus door gasket and filter changes, engineer visits and pressure vessel examinations. A failed machine test record marks that chamber on the dashboard until a passing record is entered.
Record schedules
Pick a schedule for US dental guidance, UK primary care dental guidance or veterinary use. Scheduled reminders are starting defaults. Check them against your local requirements, the sterilizer manufacturer's instructions and the biological indicator's instructions for use.
Sterilization audit PDF
Choose a date range and export a PDF containing the load ledger with cycle parameters, the biological indicator log with both vial readings, the machine test and servicing log, your practice details and your signature.
Reminders
Schedule due date and incubation read reminders, with a built-in check for the notification permissions a phone can switch off.
Works offline
Records are kept on the device and can be entered without an account or an internet connection.
WHO IT IS FOR
Dental practices, veterinary clinics and aesthetic medspas running two or more bench sterilizers, where instrument sterilization records are open to unannounced infection control inspection. Dental nurses, practice managers, veterinary technicians and medspa operators keeping this record on paper today.
IMPORTANT
SteriProof is a record-keeping and audit-assistance tool. It organizes sterilization records and reduces the paperwork around them. It does not substitute for accredited biological laboratory testing, for your manufacturer's validation schedule, or for a statutory health authority inspection.
SteriProof is not a medical device and does not diagnose, treat, cure or prevent any medical condition. Consult a qualified healthcare professional for medical advice, diagnosis or treatment.
Questions and support: support@clearstackapps.com
Recent changes:
Maintenance update: under the hood fixes and improvements.
Safety and technology
Found in the app by AppBrain- Ads
- Contains ads
- Price
- Free
- Libraries
- ?
- App size
- 26.4 MB
- Content rating
- Everyone
Technologies used by SteriProof: Autoclave Logbook
Releases
Updates seen on Google Play- Version
- 1.0.1
- Launched
- August 2026
Alternatives
Similar apps and more from ClearStack AppsAlternatives to SteriProof: Autoclave Logbook
More from ClearStack Apps
Installs
Tracked by AppBrain- Last 30 days
- 2
- Play install range
- 1+
- Launched
- August 2026
Installs over time
SteriProof: Autoclave Logbook has been installed 2 times. Over the past 30 days, it has been installed 2 times.
Rankings
Google Play top chartsGoogle Play Rankings for SteriProof: Autoclave Logbook
About the app and developer
About SteriProof: Autoclave Logbook
SteriProof: Autoclave Logbook is a medical app developed by ClearStack Apps.
How many times has SteriProof: Autoclave Logbook been installed?
SteriProof: Autoclave Logbook has been installed 2 times. In the last 30 days, the app was installed 2 times.
What is the rating of SteriProof: Autoclave Logbook?
SteriProof: Autoclave Logbook has no ratings yet.
Is SteriProof: Autoclave Logbook free?
SteriProof: Autoclave Logbook is free. The app size is 26.41 MB. The latest version available is 1.0.1. The last update was on September 24, 2026.
What are the requirements for SteriProof: Autoclave Logbook?
The app has a content rating of Everyone. The app has been available on Google Play since August 2026.
App Performance Report
Get a detailed PDF report for SteriProof: Autoclave Logbook with download trends, rating history, and key performance statistics — useful for competitive research or tracking your own app. Learn more
Get PDF Report — $29